Skip to content
Product brief · PB-EVSE-X-CL · rev 1.0 · October 2026

EVSE-X-CL Shipped

Cable lock driver

Drives the lock of a Type 2 charge socket from the charge controller's lock command, with position feedback. Reserve capacitors keep enough energy on board to release the lock after a power failure, so a car is never held on a dead charger.

Cable lock driver board EVSE-X-CL: long narrow green board with three large reserve capacitors and a 4-pole push-in terminal with orange levers
122 × 22.5 mm board: controller connector on the left, reserve capacitors in the middle, lock terminal on the right
EVSE-X-CL seen from the front
Tallest parts 20 mm above the board
Close-up of the logic end of the EVSE-X-CL with the 3-pin connector to the charge controller
Logic end: 3-pin connector to the charge controller, microcontroller and motor driver
EVSE-X-CL seen from above
Top view

In short

A small driver board between the charge controller and the lock of a Type 2 charge socket. The EVSE-C-3x32A gives the lock command; the cable lock driver turns it into a motor drive in the right direction, reads back whether the lock is open or closed and reports that to the controller.

The board stores energy in three reserve capacitors. If the supply fails while a cable is locked in, there is still enough energy to release the lock, so the car is never held on a charger without power.

Price
on request; shipped in limited quantities
CAD
STEP and drawing: edgetech.eu/cad/evse-x-cl.step

Key facts

SpecificationValue
FunctionLocks and unlocks the charge-socket lock actuator on command of the charge controller and reports its position
Controller connectionP1, 3-pin: lock signal, +12 V and GND from the lock port of the EVSE-C-3x32A
Lock connectionJ3, 4-pole push-in terminal with levers: actuator drive (both directions) and position feedback
Power-failure release3 × 2200 µF reserve capacitors keep enough energy to release the lock after loss of supply
DimensionsBoard 122 × 22.5 mm; tallest parts 20 mm above the board; keep 4 mm free below; no mounting holes, held by its edges
Wiring clearanceLeave 20 mm above P1 and above J3 for the plug, the wires and opening the levers
Lock compatibilitySocket lock actuators differ. We test each locking mechanism before supply: tell us which socket and lock you use
Control over ModbusThrough the charge controller: lock state in register 0x0010, lock with 0x0015, unlock with 0x0016; lock behaviour set by bit 1 of the settings (0x0204)
Made inEurope