EdgeTechProduct brief · PB-EDGE-CH-D · rev 2.2 · September 2025
EDGE-CH-D Shipped
Charger with display
Our main charger: the same grey box and electronics as the simple charger, with a transparent lid and a display behind it that shows charging state, current and energy. Use it as it is, or with your own shroud or front: a white-label charger under your name, with the MyCharger app under your name if you want it. From there it is a short way to your own enclosure and electronics through engineering.




In short
Sites where the user wants to see what the charger is doing without opening the app: company car parks, VvE garages, and installers who prefer to read the state at the box.
- Price
- On request
- Lead time
- Standard: produced to order, confirmed with the quotation. Own shroud: first batch 8–12 weeks after design freeze (indicative); repeat batches 4–6 weeks
- CAD
- STEP and drawing: edgetech.eu/cad/display-charger.step
Configurable
- Shroud: Standard grey box, your own shroud or front, or your own enclosure
- Branding: Front label, LED colours, app name and icon (white-label MyCharger), splash and support contact
- DC leak sensor (RDC-DD): Standard, included with every charge point
- Charge points: 1 or 2 per unit; up to 10 per site controller
- Connector: Socket with lock; fixed cable 5 m or 7.5 m
- Phases: 1-phase 16/32 A, 3-phase 32 A; per-socket 1P/3P switching for solar
- Site measurement: P1 (SC-02), CT clamps (SC-01), GridShield wireless, or none
- Firmware defaults: Modbus address, lock type, LED type, CP disconnect behaviour, min/max current
- Metering: On-board, or external MID meter
- Platform: EdgeTech-hosted platform, or your own instance of the charging platform (on-premise deployable)
- NFC reader: With or without
Key facts
| Specification | Value |
|---|---|
| Display | Behind a transparent lid; shows state, current per phase, session energy; content to be confirmed |
| Shroud / front | Standard grey box, or your own shroud or front on the same box |
| Charge points per unit | 1 or 2, each on its own EVSE-C-3x32A and EVSE-X-DCD |
| Power | 1-phase 16 A or 32 A, or 3-phase up to 32 A (22 kW) per charge point |
| Connector | Type 2 socket with lock, or fixed Type 2 cable (5 m or 7.5 m) |
| Protection | DC leakage 6 mA (RDC-DD, IEC 62955) on board; upstream Type A RCD 30 mA and MCB per charge point supplied by the installer or built in |
| Load balancing | Dynamic per-second limiting with EVSE-SC-02 (P1) or EVSE-SC-01 (clamps), or wireless with GridShield |
| App and platform | MyCharger app (iOS, Android): start/stop, off-peak schedules, solar modes, consumption overview, automatic invoicing. Installer diagnostics and OTA updates. |
| Signalling | RGB status LED or addressable LED light ring, colours configurable |
| Authorisation | Plug and charge, app start, scheduled. RFID on request. |
| Metering | On-board metering (not MID). MID meter as an option for billing. |
| CE | Charge controller and site controller carry their own EU declarations of conformity; updated declarations (EN IEC 61851-1:2019, EN IEC 61851-21-2:2021, RED with EN 18031) soon. The assembled unit is declared by the party placing it on the market; we supply the technical file. |
| Manufactured | Boards and assembly in the Netherlands / EU |