Skip to contentCharger not charging? Check it here →

Support

FAQ

The questions installers and charger owners ask most: faults and diagnosis, the site controller, app and subscription, charging and load balancing, solar charging and the P1 module, vehicle-specific problems, MID and certificates, installation, returns and repair, Home Assistant and evcc.

View as MarkdownUpdated 2026-10-26

Customer FAQ, compiled from the full support history 2021–2026. Status: October 2026. Prices are excl. VAT unless stated otherwise and apply as of the date given.

Charger not charging or offline? Check it yourself by its code: you see right away what it is doing and why.

Contact support: support@edgetech.eu · https://www.edgetech.eu/ With every fault report, send right away: a clear photo of the QR code on the site controller in the metering cabinet (not the one on the charger itself!), a short description and what you have already tried.


1. Faults & diagnosis

My charger does nothing at all (no lights, no response). What now?

First do the quick reset: unplug the car → switch the charger’s RCD off for 3 seconds and on again → plug the car back in. (Note: cutting the power for 30 minutes does not reset it; a short off/on does.) If that doesn’t work, there are three possibilities:

  1. RCD faulty (have your installer check this). Use a voltage tester (only a voltage tester, because of the risk of electric shock — see https://nl.wikipedia.org/wiki/Spanningzoeker) to check whether there is voltage on the brown wire to the large grey terminal marked “L1”. Carefully insert the voltage tester into the rectangular slot above the wire. Light on = RCD is fine. Hey!/Luxe Laadpaal: if the LED strip on the charger is lit, the RCD is fine. If it is not lit while the RCD in the distribution board is on, the RCD is broken and must be replaced (installer).
  2. Charge controller (board) faulty (have your installer check this). Open the charge point’s enclosure (with the supplied key if needed). Don’t touch anything, only look: next to the grey terminal with two orange levers there is a green LED that should blink briefly every ±3 seconds. If it doesn’t blink, or no LED on the board is lit at all → charge controller faulty, replace it (see section Returns & repair).
  3. Fault condition. If the red LED is blinking: (a) unplug the car, (b) switch the RCD off for 3 seconds and on again, (c) check that the red LED is off.

Then send a photo of the site controller’s QR code to support. We look along remotely and can restart the installation remotely.

A red light is blinking / the app shows “DC earth leakage” (“DC-aardlek”). What does that mean?

The charger has a legally required RDC-DD that trips at a DC residual current of 6 mA or more (a DC leak can saturate the normal AC RCD so that it no longer trips, which is why the charger switches itself off). Reset: unplug all cars → RCD off for 3–5 seconds → on again → plug the car in. Just switching the RCD without unplugging the car does not work.

If the fault keeps coming back, the cause is almost always external:

  • The car: test at a new public AC charger (fast chargers don’t count: DC charging is a separate system, and older public chargers often have no DC detection). If it only happens with one car → have the dealer check the charging system and report “DC leakage current ≥6 mA detected” (“DC-lekstroom ≥6 mA gedetecteerd”).
  • The earthing of the house: with an earth rod, have an installer measure the earth resistance (<30 Ω).
  • Recent changes: a home battery or extra solar panels can be the trigger. Report this to support.
  • Moisture in the plug, charging cable or enclosure (do not use the rubber protective cap on the plug of the fixed cable: water collects in it).

The RCD or main fuse trips while charging.

Most common causes:

  • Charge current too close to the circuit breaker rating: the set charge current must be well below the circuit breaker rating (no 32 A on a B32; advice: 3-phase RCBO 3x16A, type B, 30 mA). If the 32A jumper is fitted on the board while there is a 16A circuit breaker → remove the jumper.
  • Load balancing not working because the data link site controller ↔ charger is broken: restore the link (see section 2). Otherwise the charger charges unbalanced and the main fuse can trip.
  • Two single-phase cars on the same phase (dual charger): have a different mains phase connected to L1 at one charge point (on the supply side).
  • If the RCD trips “for no reason”, it can also be a real (DC) earth leak. See the question above.

I get the message “board error” / “internal error” (“interne fout”).

A board error means that the site controller cannot read the charger’s internal current measurement unit. Once is harmless: switching the RCD off/on for ~5 seconds (or asking support for a remote restart) almost always solves it. If the message keeps coming back, the charge controller needs replacing.

I get “car connected/disconnected” (“auto aangekoppeld/ontkoppeld”) messages while no car is plugged in.

Ghost messages are caused by a hanging site controller (a restart solves it), water in the plug, a loose CP contact, or, after a board replacement, the old charge controller still being in the configuration (support removes it server-side; reinstalling the app clears what is left).

The charger only charges at ~10 A and reports a high temperature.

At an internal temperature of 62 °C the charge controller drops back to 10 A. At an even higher temperature, charging stops (with a message in the app). This happens with a charger in full sun and with long single-phase charging. Advice: shade or a sun screen. On a temperature message, unplug all cars and restart the charge point with the RCD.

The charging cable is stuck in the charger.

Briefly cut the power to the circuit (RCD). That unlocks the cable. Then switch the circuit back on to be able to charge.


2. Site controller & connection

The app says “Site controller offline” (“WiFi-module offline”). How do I get it back online?

Standard procedure (grey site controller, EVSE-SC-01):

  1. Make sure no car is plugged in.
  2. Remove the cover of the distribution board. Check the LED: slowly “breathing” cyan (light blue) = online/OK.
  3. Restart: switch the circuit that feeds the site controller off for 30 seconds and on again, or briefly press the recessed “R” button (next to the LED) with a satay skewer or toothpick (something that does not conduct: the wires behind it carry 230 V). The site controller should come back online within ±1 minute (LED breathing cyan again).
  4. Only if your WiFi network has changed (new router, different name or password): press the button with the WiFi symbol for ≥3 seconds until the LED blinks dark blue (setup mode). A site controller that was already connected then restarts by itself: the LED goes off for a moment and blinks dark blue again — wait for that. Then, in the MyCharger app, go to the gear icon top right > General settings (“Algemene instellingen”) > WiFi and enter the network and password again. You don’t need to reinstall the app for this.
  5. If it still doesn’t work: delete the app, reinstall it and scan the site controller’s QR code from within the app.

Black site controller (new P1 generation, EVSE-SC-02): restart = pull the RJ12 plug out of the smart meter’s P1 port for 3 seconds (or unplug/replug the splitter plug). Set up WiFi again = press the “Mode” hole with a paperclip for 3 seconds (the “general” LED blinks dark blue), then pair via the app.

Support can usually also restart the site controller remotely.

What do the LED colours on the site controller mean?

Grey site controller (EVSE-SC-01), and the “general” LED of the black EVSE-SC-02:

  • Cyan, slowly breathing (steady on the SC-02) = connected to the EdgeTech server, all OK
  • Cyan, blinking = not connected to the EdgeTech server yet: WiFi or internet is still connecting, or is down. Load balancing keeps working
  • Steady blue = a car is plugged in at one of the chargers (SC-01 only)
  • Dark blue, blinking = setup mode (the module broadcasts its own temporary WiFi network)
  • Green, blinking or breathing = no active subscription; load balancing keeps working
  • Yellow, blinking slowly = searching for chargers on the Modbus cable
  • Orange, fading (yellow blinking on the SC-02) = the charger’s software is being updated
  • Magenta, blinking = software update of the site controller (if it gets stuck: R button)
  • Red, blinking fast = factory reset armed (the WiFi button was pressed 4 times quickly). Do nothing and it cancels itself after 5 seconds
  • Red, steady = factory reset in progress

The black EVSE-SC-02 also has five single LEDs: power, network and cloud steady green = all OK; activity flashes green about once a second while all chargers answer, and the red error LED flashes instead when a charger does not answer. The installation manual has the full table.

In short: light blue, slow = good; dark blue blinking = set up WiFi; anything else = restart.

The site controller keeps going offline. What can I do?

The site controller only works on 2.4 GHz WiFi. Known culprits: separate 2.4/5 GHz bands, mesh systems that keep changing the 2.4 GHz channel (then fix the channel manually), routers with an “eco” or night mode, heavily secured networks, and modem updates from the provider after which devices no longer reconnect automatically (restart the router). With a weak signal all the time: place an extra 2.4 GHz access point with its own network name close to the metering cabinet. Check that everything works: you should get a push notification every time you plug in or unplug the car.

My charger sometimes stops charging, or doesn’t start again.

Charging itself runs locally, but the site controller also keeps a connection open to our server, over your WiFi and your internet. A good WiFi signal alone is not enough: your router must also keep that connection open. If the connection keeps failing, the site controller sets it up again, and after a long outage it restarts itself. Each time, a running charge can be interrupted, and some cars do not start again by themselves (see section 6 for cars that don’t wake up). What to do:

  1. Restart your router or modem.
  2. Check security filters in the router or from your provider (“safe browsing”, parental control, ad or malware blocking, DNS filters). Allow the site controller, or switch the filter off for a day as a test.
  3. Keep the router’s firmware up to date.
  4. As a test, connect the site controller to another access point or router.
  5. Does it keep happening? Mail support@edgetech.eu with your code.

The charger check shows whether the WiFi or the internet connection of your charger is unstable.

Important: the order when switching off/restarting

The site controller only searches for charge points while starting up. So never restart the site controller while the charger has no power (holiday, work in the metering cabinet). The charge point then “disappears” and nothing more is recorded. Correct order: first power the charger, then (re)start the site controller. Also don’t hard-switch the charger off with the RCD every day; use “allow charging” (“laden toestaan”) or schedules in the app.

Nothing is recorded any more, but charging still works.

Almost always one of these causes: site controller (silently) offline, wrong start-up order (see above), broken data cable between site controller and charger, or an expired subscription. Note: missed individual sessions cannot be reconstructed afterwards. The total kWh charged is added automatically at the next session (as one “unknown session”), and support can always read the total counter.


3. App & subscription

Which app should I use?

MyCharger (one word). Make sure you have the latest version of MyCharger:

If you still have an older charging app for this charger on your phone, delete it first. Your settings, subscription and charging history are kept (they belong to the site controller, not to the app).

How do I pair the app (new phone, reinstall)?

  1. Delete the app and reinstall it.
  2. On first start, allow all notifications (registration works via push messages).
  3. Choose “scan QR code” and scan the QR code on the site controller in the metering cabinet from within the app. So not with the normal camera/QR scanner (that takes you to the payment page) and not the QR code on the charger itself.
  4. Only fill in your contact details; everything else is already configured. If the site controller is already online, the WiFi step is skipped.

iPhone tip: if the site controller does need to be set up over WiFi, connect manually via Settings > Wi-Fi to the module’s temporary WiFi network and go back to the app (Android does this automatically).

How do I give a second user/phone access?

With an invitation code (valid for 24 hours). In the main user’s app: Settings (gear icon) > Charger > Access (“Toegang”) > add/share user. The new user installs MyCharger and chooses “enter code” (“code invoeren”) during setup (so not scan QR). If you want sessions recorded per user: switch Plug & Charge off (Settings > Charger). Everyone then starts each session from the app and appears by name in the usage overview.

Is a subscription required? What works without one?

Since 1 January 2025 a subscription is required for: the mobile app (remote start/stop), usage overviews/charging history (expense claims), new features in software updates and remote help. Without a subscription, charging, plug & charge and dynamic load balancing always keep working. The charger is never made “dumb”; fixes and security updates remain free. Note: with an expired subscription, session recording stops silently and the site controller is eventually disconnected from the platform. Charging history for that period cannot be recovered.

The subscription belongs to the site controller, not to your phone, app or account. So one subscription covers several phones, and a different app or a reinstall costs no subscription days. Existing long-term subscriptions stay valid until their end date. You don’t need to cancel (it ends automatically, and you get a push notification beforehand). When you renew, remaining days are always added on, so you never lose days.

How do I take out or renew a subscription?

Three routes (all current, October 2026):

  1. Tap the banner/notification in the MyCharger app, or in the app: gear icon > General settings > details of your site > subscription.
  2. Portal: https://mycharger.edgetech.nl/. Direct payment page per device: https://mycharger.edgetech.nl/page-4/index.html?device_code=<QR-code>.
  3. Scan the QR code on the site controller with your phone’s normal camera and follow the link (short link: https://evqr.nl/).

Terms: ½, 1, 2 or 5 years; six months € 32.50, a year € 61.50, incl. VAT. If the payment page hangs, you can pay by bank transfer: €32.50 / €61.50 / €119.80 / €284.00 (½/1/2/5 years) to Edge-FS B.V., IBAN NL34 BUNQ 2070 3239 00, quoting your site controller’s QR code. Payment link e-mails regularly end up in the spam folder. Old payment links from earlier years no longer work; ask support for a new one if needed.

What was the 2026 platform migration, and do I need to do anything?

Because the cloud provider’s costs have risen sharply, the MyCharger platform moved to a new environment in 2026 (data stays in the EU). You were informed by e-mail (mailing “Important information about your charger” (“Belangrijke informatie over uw laadpaal”), 22 May 2026). The migration is complete.

  • Site controllers sold now come with the latest firmware and are supported after 1 July 2026 too. Installers and households can buy them.
  • The 1 July 2026 date was for older site controllers from before the migration. Without a subscription they were not in the old cloud and could not be migrated. You can still send such a site controller in; we update it for € 50. Mail support@edgetech.eu with your code first; we reply with the address and how to pay.

How do I download my charging data for expense claims?

MyCharger: under the plug icon > Usage (“Verbruik”) > choose a period > download as CSV or HTML, then share/e-mail. Tips: the CSV uses “;” as separator (HTML looks nicer on a phone); a kWh price can be set; sessions only appear after the car is unplugged and count in the month of the start time; the times shown are plug-in/unplug times, not pure charging times. The recorded kWh can be up to ~15% higher than what goes into the battery (cable and conversion losses, which is normal).

The app shows a strange status or behaves oddly.

Standard remedy: delete the app, reinstall it, scan the QR code from within the app. On Android, with persistent problems, first go to Settings > Apps > MyCharger > Storage and clear the cache and the data. You send a diagnostic report to support via app > Settings > Expert > Send report (“Verzend rapport”).


4. Charging & load balancing

The car doesn’t charge (or stops) as soon as the heat pump/oven/washing machine is on. Is the charger broken?

No, this is correct behaviour. Dynamic load balancing measures the consumption of the whole house and only gives the car the remaining current, so your main fuse is never overloaded. Rules of thumb: a car needs at least 6 A (starting current 8 A), many cars only charge from 10–12 A, and large 3-phase cars (Audi e-tron, Porsche Taycan, Renault Zoe) not below ±13–14 A per phase. On a 3x25A connection with a running heat pump, there is sometimes simply too little left on cold days. Solutions: separate heavy loads and charging in time (e.g. pause the heat pump 23:00–04:00), have an electrician spread heavy loads over the phases, or have the grid connection upgraded (3x25 → 3x40A solved several cases). As soon as there is room again, charging resumes by itself (can take up to ±1 minute).

Warning: a separate “granny charger” on a normal socket bypasses load balancing and can make the main fuse blow.

My car only charges at 3.7 kW while I expect 11 or 22 kW.

Do the maths first: 1 phase × 16 A = 3.7 kW; 3 phases × 16 A = 11 kW; 2 phases = 7.4 kW. Many (hybrid) cars can only charge single-phase (all PHEVs ~3.7 kW; Hyundai Kona before 2021; Jaguar iPace; Nissan Leaf single-phase up to 32 A) and some VWs/Audis charge on 2 phases. If you really want 32 A (up to 22 kW): the hardware jumper must be fitted on the board (“16A open / 32A short”) and the charging cable, circuit breaker and connection must be able to handle it. Discuss this with support/your installer. If a 3-phase car always charges on 2 phases (~7.2 kW), a phase wire is almost certainly loose. And: above ~90–95% battery, every car throttles back by itself. That is normal.

How does a dual charger work with two cars?

The first car plugged in gets all available current. The second gets the rest and waits if needed until the first is (almost) full. Sequential charging is by design and also more efficient. Two single-phase cars at the same time: have charge point 2 connected to a different phase. Never switch the RCD while a car is charging at the other charge point.

Can I switch between single-phase and 3-phase, or charge more gently?

Yes. In MyCharger: Settings > Expert > switch on the beta function “Switch 1/3 phase” (“Schakel 1/3 fase”). You then switch from the main screen (rolled out end of July 2025). Single-phase ≈ 1.5–3.7 kW, ideal for solar charging. Don’t switch too often within one session (some cars go into a fault state), and preferably with the plug disconnected. The setting Expert > Charge current (“Laadstroom”) deliberately has a lower limit of 16 A. It is meant for limited connections, not for charging more gently; use single-phase for that.

Delayed charging doesn’t work / has to be entered twice.

Entering it twice was a known app bug (the second entry is the one that counts). For daily charging at a fixed time, tick “daily”. If the car doesn’t start at the set time, it is almost always the car not waking up from a 0 A phase (see section 6). Never set charging schedules twice (in the car’s app and in MyCharger); choose one. Test: switch on charge-now → plug in the car → switch “allow charging” off → wait ≥5 min → switch it on again. If the car only charges after unlocking it, the car has the known “doesn’t wake up” problem. Edgetech can then send a hardware interrupter for the CP contact free of charge (let us know in advance; it comes with a software update).

I have to switch on “allow charging” every time before the car charges.

Then Plug & Charge is off. This is a deliberate setting that stops strangers from charging at your charger and records sessions per user. If you want the car to charge as soon as you plug in: switch Plug & Charge on via Settings > Charger.


5. Solar charging & the new P1 module (EVSE-SC-02)

Can I charge on my own solar surplus?

Yes, with the “Smart & Solar” (“Slim & Zon”) function in MyCharger. Required: the new black site controller EVSE-SC-02, connected directly to your smart meter via the P1 port (RJ12), and a smart meter with DSMR/ESMR 5.0 or newer. The site controller follows the solar output dynamically (3-phase 8–16 A ≈ 5.5–11 kW, adjusting ~every 10 s), with adjustable thresholds (only start at ≥X kW solar; at least X kWh per day, topping up from the grid as a safety net). Charging 100% on solar is not practical (winter). The system deliberately does not switch automatically between 3-phase and single-phase (too many cars go into a fault state); manual single-phase (1.5–3.7 kW) is the fine-grained option. If you want continuous fine control: see EVCC in section Smart integration.

Is my smart meter suitable?

DSMR 5.0 or higher is required: the meter must send a telegram every second and supply ≥250 mA on the P1 port. DSMR 4.2 is deliberately not supported (too slow for load balancing). Note: ZIV meters labelled “ESMR5” (EAN starts with E0069) behave like DSMR4.2 and are unsuitable. Unsuitable meter? Request a meter replacement from your network operator (often free) (Liander: https://slimme-meter-aanvragen.web.liander.nl/; Enexis replaced one for €212). Symptom of an unsuitable meter: a steady red error light and a site controller that keeps restarting. If there is already a P1 reader on the meter: use an active splitter (recommended: HomeWizard active P1 splitter).

What does switching to the new site controller cost?

Current offer (2026): trade-in/upgrade €95 excl. VAT (old site controller + CT clamps returned), EVSE-SC-02 on its own €145 excl. VAT, plus shipping (~€5.95–6.35). Your running subscription term is transferred. (History: earlier offers with an €85 trade-in and cashbacks of €45–60 have ended.) You can do the installation yourself. Instruction video: https://vimeo.com/1092705947/25b25ff275. Send a photo of your smart meter beforehand (suitability check) and of the data cable colours. After installation: reinstall the app and scan the new QR code. Only remove the old site controller once the new one works.

Why would I upgrade if I don’t have solar panels?

The old grey site controller (CT clamps) does not always determine the direction of the current correctly when you feed back to the grid, and supports max. 4 charge points. The new one reads the meter directly (more accurate) and can handle 8–10 charge points. If you have no PV and no measurement problems, there is no need to upgrade.


6. Vehicle-specific problems

My Audi doesn’t charge at night / doesn’t resume charging (Porsche too).

A known structural car problem (not a charger problem): the charging controller of the Audi Q series up to ±2022 (and the Porsche generation with the same charging system) falls into deep sleep after about 5–15 minutes at “0 A” (load balancing or delayed charging) and doesn’t wake up again. Cause: a software bug in the car’s charging control. Solutions:

  1. Audi software update campaign 93N9: check whether your VIN qualifies via the myAudi app or https://my.audi.com > Service > Digital Service Planner > Actions.
  2. Set the charging schedule in the car itself (not in the MyCharger app), e.g. 23:00–04:00. There is then almost always room to charge (≥55 kWh per night). Make sure the heat pump doesn’t start before 04:00.
  3. Edgetech can activate the EV wake-up function on the charge controller (helps partly). Porsche has solved the problem with its own software update. Newer Audis (Q series ≥2023, A6 e-tron, Q8 e-tron) charge without problems. In the car’s app, always switch off “optimised/optimal charging” and double charging timers.

My Peugeot (e-208/e-2008) stops and doesn’t start again by itself.

The same family of problems: after a 0 A interruption the car stays stuck in “connected” until it gets a nudge: lock/unlock with the key, or unplug and replug. Ask the dealer for a software update. Renault Zoe, Dacia, Kia, Tesla and Volvo do resume properly.

My car charges everywhere except at home.

Think of: a loose or oxidised CP contact in the plug/cable (always push the plug in firmly and straight), moisture in the connection, a charging schedule or charge limit in the car itself, or “optimal charging” based on location. If a different car does charge at your charger, the car is almost certainly the cause. Always report make, model and year; support then looks along with debug logging. Known unsolved case: Hongqi gets no further than “connected” at these chargers (escalation with the manufacturer is ongoing).

Can the charger damage my car (the on-board charger/OBC)?

No. The charger only puts voltage on the wires and advertises the maximum current; the car decides itself how much it charges. An on-board charger cannot be damaged by a charger that isn’t working, only by an internal short circuit or a large fault current (e.g. a strongly raised mains voltage caused by inverters).

Small current draw at night while the car is full?

±0.5 A (100 W) is the car’s own battery/temperature management. Normal.


7. MID meter & ERE certificates

Can I earn money with my charger through ERE certificates?

Yes, provided there is a MID-certified kWh meter in it. The built-in Edgetech meter is not MID-certified. The solution: fit a MID-certified 3-phase kWh meter (100 A, ~€60–70) inside the charger enclosure, in series before the charge controller. You may do this yourself (there is no legal requirement for a qualified electrician or “factory sealed”). Edgetech sends mounting brackets free of charge (shipping costs only), and De Jong EKW (Apeldoorn) can also do the fitting. To cash in: register at https://laadloon.nl (accepts a photo of the meter; yield ±€300/year at ~3000 kWh charged). If a registration service refuses a retrofitted meter, choose another one; the law allows it.

Note the rules (as of 2026): 2026 is a transition year in which a separate MID meter in the metering cabinet is still accepted. From 1 January 2027 the MID meter must be inside the charger enclosure.


8. Installation

Which data cable goes between the site controller and the charger?

A 3-core cable of 3 × 0.75 mm², flexible (stranded), not solid-core. The three cores: GND, A+ and B-. No loose Ethernet/UTP/Cat5/Cat6 cable in the screw terminals or terminals: the thin solid cores break sooner or later, especially without strain relief and with sharp bends. Ethernet cable only with connectors (a patch cable with RJ45 plugs). On request we supply a small board with an RJ45 socket that the wires are soldered to. Quick cable test: disconnect the cable at the charger end (leave it connected to the site controller) and measure the resistance between A and B. It must be between 100 and 1000 Ohm; otherwise the cable is broken.

I’m fitting a fixed charging cable. What do I need to know?

With a fixed charging cable (or a cable with an open end), the PP wire (proximity pilot) must NOT be connected. It is only used with a Type 2 socket. The CP wire goes to the terminal “PILOT”. Don’t extend the cable (>8 m is prone to faults) and don’t use the rubber protective cap on the plug (water collects in it).

Which circuit breaker and cabling?

Recommended: 3-phase RCBO 3x16A, type B characteristic, 30 mA, with the charge current setting well below the circuit breaker rating. Power cable min. 2.5 mm² for 11 kW (short distances). The RCBO, distribution board and cabling to the charger are your installer’s responsibility; Edgetech supports the electronics. Preferably put the site controller on a different circuit from the charger, and never inside the charger enclosure (no WiFi range).


9. Returns & repair

The charge controller (board) is faulty. How does the replacement work?

Edgetech sends a replacement board (1–2 days, DPD/DHL with track & trace and a return label; note: the return label is only valid for ±5 days). Replacing it yourself takes ±30 minutes, is 100% safe once the RCD is off, and is much faster than a technician (≥3 weeks waiting time). The 7 steps:

  1. Power off (RCD off); open the enclosure with the special key.
  2. Take a photo of the wiring, with a close-up of the data cable on the grey terminal with three levers.
  3. Disconnect the wires: cores of the power and charging cable by putting a narrow screwdriver in the rectangular hole above the core; orange levers up for the rest.
  4. Remove the board, fit the new one.
  5. Reconnect the wires exactly as in the photo; no loose copper strands.
  6. Send photos of the result (per terminal) to support for checking.
  7. Only after support has approved, switch the RCD back on. Support can guide you by phone if you like, and then updates the configuration and software remotely (send the site controller’s QR code along). Afterwards, plug in a car once so the charge point is found again; reinstall the app so the old charge controller disappears. While you wait, you can charge with the supplied “granny charger” (“oma-stekker”) or at a public charger.

What does it cost?

Current guide prices (2025–2026, excl. VAT):

  • Refurbished charge controller: €95 (2-year warranty) + shipping ~€6
  • New charge controller: €120; RDC-DD: €25; set of charge controller + RDC-DD + 2 mounting brackets: €125
  • New site controller EVSE-SC-02: on its own €145; as trade-in/upgrade €95
  • Technician on site: €155 on top of module + shipping (waiting time ≥3 weeks; if the module turns out to work fine during the visit, the costs are for the customer, so do the LED self-diagnosis first) Within the 2-year warranty (packing slip date = purchase date), faulty modules are replaced free of charge. Water damage is not covered by the warranty. Complaints about the enclosure go through the seller.

Where do I send a faulty module?

Faulty modules always come back to us (for repair/analysis), preferably in the purple antistatic plastic with a short description of the complaint. Current return address: Edge FS B.V. / Edgetech BV, attn. F. Boddeke, Brigittenstraat 11, 3512 KJ Utrecht (alternative shipping address: attn. S. Wallage, Rustoordlaan 35, 7211 AV Eefde). Postage you paid yourself is refunded (send us your IBAN).

I’ve had a faulty board more than once. How is that possible?

The old board generation (up to early 2023) had a fragile transformer in the power supply, responsible for ~95% of the faults. The new generation (shipped from spring 2023) is robust; almost no returns are known. With a repeat fault, an old unit may have been fitted again at the time. Let us know, and you will get a charge controller of the new generation.


10. Smart integration (Home Assistant, EVCC, API)

Can the charger work with Home Assistant / Homey?

Yes, via the cloud API (subscription required): documentation and ready-made configuration files at https://mycharger.edgetech.eu/. You download the files via MyCharger > Settings > Expert. Homey and Google Home connect via the Home Assistant integration.

Does it work with evcc?

Yes. Our charge controller EVSE-C-3x32A, in every EdgeTech-based charger and in the DIY kit, is an official evcc device (“Edgetech Smart EVSE”), and EdgeTech maintains the evcc template. You only need the charge controller: evcc talks to it over RS485 and does the load balancing, solar charging and dynamic tariffs itself, so no site controller is needed. See evcc and Home Assistant.

Can I control the charger fully locally, without cloud or subscription?

Yes, with EVCC (https://evcc.io, open source): the charger is officially supported as “Edgetech Smart EVSE”. You need: a small Linux computer + a USB-RS485 adapter (settings: 9600 baud, 8N1, and the Modbus address the site controller gave the charger; a new charger is at address 1 and only answers there after a state change, so first give it address 2 or higher via register 0x0200). The Edgetech site controller is then disconnected. You get fine-grained solar charging and integration with dynamic tariffs (Tibber etc.), but no control outside your own network and no remote support from Edgetech. DIY documentation: https://github.com/edge-tech-eu/SmartEVSE/blob/main/docs/en/diy-chargepoint.md (all open source).


Reporting a fault: checklist

Send to support@edgetech.eu:

  1. A clear photo of the QR code on the site controller in the metering cabinet (without this code, remote diagnosis is not possible);
  2. A short description of the fault + what you have already tried;
  3. Photos of the installation, including the LED status of the site controller and charge point;
  4. Make/model/year of the car and any error messages from the car or app;
  5. If possible, a diagnostic report via the app: Settings > Expert > Send report.